Asian Spine J Search

CLOSE


Asian Spine J > Volume 12(2); 2018 > Article
Dobran, Nasi, Esposito, Gladi, Scerrati, and Iacoangeli: The Incidence of Adjacent Segment Degeneration after the Use of a Versatile Dynamic Hybrid Stabilization Device in Lumbar Stenosis: Results of a 5–8-Year Follow-up

Abstract

Study Design

Retrospective study with long-term follow-up.

Purpose

To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis.

Overview of Literature

The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated.

Methods

Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology.

Results

The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p<0.0001 and p<0.0001, respectively). At the 5–8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation.

Conclusions

Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5–8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation.

Introduction

For many decades, lumbar fusion surgery has been considered the gold standard surgical technique for patients suffering from chronic lower back pain caused due to degenerative disease and instability. Although favorable clinical outcomes can be achieved, complications of lumbar fusion with rigid fixation have gained increasing attention [1]. For many researchers, fusion is one of the risk factors for adjacent segment disc degeneration, with an incidence rate of 14%–70% of operated patients [234]. Currently, many dynamic devices are available for lumbar spine dynamic stabilization, and each has specific technologies which attempt to preserve the physiological range of motion of the lumbar spine [234567]. Adjacent segment degeneration (ASD) may be caused due to altered biomechanics of the fused spine producing abnormal forces on the adjacent spinal levels with degeneration of the rostral disc adjacent to a rigid stabilization [8]. ASD is defined as new degenerative changes at the spinal level, adjacent to surgically treated level or levels in the spine, accompanied by related symptoms (radiculopathy, myelopathy, or instability). The instability is assessed using dynamic X-ray examination. Disk degeneration disease represents the radiographical changes without symptoms [9].
Posterior dynamic stabilization could ensure a relatively normal range of motion of the instrumented segments, thus avoiding the rapid degeneration of the adjacent intervertebral disc [101112]. Dynamic stabilization is indicated in cases of degenerative disc disease or may be used in patients with lumbar spinal stenosis treated with extensive laminectomy to prevent long-term spinal instability, especially when preoperative magnetic resonance imaging (MRI) shows pathological disc changes at the same or adjacent level to the planned laminectomy [91314]. This study was performed to evaluate the clinical outcomes and incidence of ASD syndrome 5–8 years after performing extensive laminectomy and dynamic or hybrid stabilization utilizing the Flex+TM system for treating lumbar spinal stenosis (SpineVision, Antony, France).

Materials and Methods

The Flex+TM device is a rod that can be used with pedicle screws. It is made of rigid titanium alloy (TA6V) end pieces combined with a dynamic segment consisting of a twisted titanium alloy cable covered with a polycarbonate urethane polymer (Fig. 1A, B).
Twenty-one patients were included in this study from September 2008 to May 2011 (10 males and 11 females). The mean age at the time of surgery was 64.3 years (range, 49 to 77 years). All the patients who were affected by lumbar stenosis and suspected to have post-decompression instability were treated with wide laminectomy (including partial demolition of the facet joint) or posterior foraminotomy followed by stabilization utilizing Flex+TM (dynamic or hybrid construct, SpineVision). The indication for a one-level dynamic stabilization was a preoperative MRI providing evidence of a pathological disc (Pfirmann 2-3-4) at the same level as that of the planned laminectomy. The hybrid device (one-level dynamic stabilization and multilevel rigid fixation) was used in cases of a multilevel laminectomy with associated initial degenerative scoliosis (Schwab classification VB0), first-grade spondylolisthesis, or a rostral pathological disc [1516] (Fig. 2A–C). None of the patients had undergone any previous spinal surgery. The dynamic device was used in 12 patients (group A) and hybrid device in nine (four patients at two levels, five patients at three or more levels; group B). All operated patients had disabling low back pain not responsive to a conservative treatment continued for at least 6 months prior to their surgical procedure. Patients with infections, tumors, severe scoliosis and spondylolisthesis, diabetes and, metabolic diseases were excluded from this study. Preoperative clinical and radiological evaluation consisted of a neurological examination, Visual Analog Scale (VAS) and Oswestry Disability Index (ODI), preoperative MRI, and dynamic X-ray. Follow-up visits, including clinical and radiological assessments, were conducted at 3, 12, and 24 months (mean follow-up, 12 months) following discharge (Fig. 3A) and final control at 5–8 years after surgery. All operations were performed under general anesthesia with the patient in a neutral and prone position; the surgical approach was along the midline, and the extension of laminectomy was performed according to the clinical data. Screws (PLUS, X-PLUS pedicular screws; SpineVision) were placed under fluoroscopic visualization. Statistical analyses were performed using the Mann-Whitney test and Student t-test. All patients granted permission for this study before surgery. All preoperative patient data are summarized in Table 1.
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The institutional review board or similar entity approval was not necessary for this study. The risk to participants was minimal. The research data analysis did not affect the participants and their medical care. Informed consent was obtained from all individual participants included in the study.

Results

At admission, the mean ODI and VAS score were 40.1% and 7.2, respectively. At the 6-month follow-up, the mean ODI and VAS score were 12.7% and 2.2, respectively; these differences were statistically significant (p<0.0001 and p<0.0001) (Table 2). The mean ODI and VAS score improvement in group A was 23.2% and 4.8, respectively (p=0.0005 and p=0.0001) (Table 3). The postoperative six-month VAS score modification (p=0.0006) as well as the ODI score (p=0.0003) in group B were statistically significant. In this group, the mean ODI and VAS score improvement were 33.6% and 5.3 (Table 4). Matching the patients with a preoperative ODI score of >40% and <40%, we obtained a greater improvement in the first group with a mean variation of 34.3% and 19.4%, respectively (p=0.0068). No significant differences were observed between the VAS and ODI score variations between patients treated with dynamic or hybrid device (p=0.4636 and p=0.1325).
There were two complications (one dural tear and one infection) which required a second operation. In the infected patient, the debridement of infected tissue did not require the removal of screw fixation as reported in the literature [6]. A the 5–8-year follow-up, clinical examination, MRI, and X-ray controls showed an ASD complication with pain and disability in one of 21 patients. Thus, clinical and MRI incidence of ASD in this study was 4.76%.
In the remaining 20 patients, the mean VAS score was 2.2 and the mean ODI score was 14.3%, which was consistent with a good outcome. The patient requiring repeated operation was not included in the statistical analysis. The patient with ASD had a three-level stabilization (L4–L5–S1) with the hybrid device (rigid L4–L5, dynamic L5–S1) (Fig. 3A, B)and underwent an extension of laminectomy to the above levels and six-level rigid stabilization (L1–S1) 5 years after the original operation. No instrumentation failure occurred in this series to date.

Discussion

ASD following lumbar fusion may result in a variety of complications, especially in case of severe back pain not responsive to conservative therapy [41718]. This condition, at least from a radiological point of view, is quite often related to a failed back spinal surgery. ASD remains a debatable issue because many researchers are uncertain if it is the natural evolution of an aging spine or is related to a previous fusion [1234567891011121314151617181920212223]. However, reports in the literature demonstrate the occurrence of clinical ASD in approximately 30% of operated patients. Age of the patient and a long segment fixation may be predisposing factors [1923]. The etiology of ASD is likely to be multifactorial, involving the supporting musculature, external loads, and a combination of forces. We must remember that patients requiring an operation for segmental degeneration may have a higher risk of further degeneration than those not requiring surgery. However, a contributing factor in ASD may be a rigid spinal fixation system [1213]. The length of the fusion has been found to be related to the occurrence of ASD, ranging from 32% for a one-level fusion to 66% for three or more levels [14].
Over the past 20 years, many lumbar dynamic devices have been introduced to reduce the incidence of ASD. In the present series, we used the same dynamic devices in all patients (Flex+TM system, SpineVision) to stabilize a single spinal segment while the hybrid device was used to treat two or more segments to prevent the evolution of the degenerative disc disease and the development of a post-laminectomy instability. Moreover, the hybrid device seems to be useful in patients who have undergone a multilevel laminectomy to grant stability at the decompressed levels and protection to the adjacent disc segment. Dynamic stabilization seems to achieve satisfactory clinical outcomes even in cases presenting with disabling preoperative pain. This was evident from the considerable ODI score improvement in patients with preoperative ODI scores >40%. The clinical improvement of patients treated with dynamic versus hybrid devices was not statistically significant, indicating that both the types of constructs are effective. We had no complications related to the implants or materials used in the system. Thus far, there have been no reports of pedicle screw loosening in patients with dynamic implants [1234567891011121314151617181920212223]. In our patients, the long-term follow-up was important to indicate a true rate of subsequent symptoms requiring reoperation for ASD because it was observed in only one of the 21 operated patients.
In several studies, the prevalence of ASD and reoperation rates were higher in lumbar fusion procedures than in motion preservation procedures.
A recent meta-analysis revealed that the prevalence of ASD in the fusion group was 14.4 whereas that in the motion preservation group was 5.1% [22]; the reoperation rate in the fusion group was significantly higher than that in the motion preservation group. In their meta-analysis, several dynamic devices were included other than the Flex+TM system. The present study confirmed these data with the use of the Flex+TM device (SpineVision) during a long-term follow-up period. In fact, in our series, the reoperation rate for symptomatic ASD was 4.76% (one patient out of 21). This could be explained by the fact that the motion preservation device protects the spine from mechanical overload imposed by a rigid fixation of the spine while retaining spine movement and preventing ASD.
The Flex+TM device (SpineVision) is a recently available dynamic and hybrid stabilization option that may be useful in preventing post-laminectomy instability as well as adjacent disc degeneration. In the present series, we used the dynamic device for single segment stabilization to protect the involved disc against further degeneration. In cases of multilevel laminectomies with an associated initial degenerative scoliosis (Schwab classification VB0), first-grade spondylolisthesis, or an adjacent pathological disc, a hybrid device was implanted to stabilize the decompressed level, protect the adjacent disc with the dynamic segment of the rod, and avoid late spinal instability of the rigid segment. From our experience, the Flex+TM device (SpineVision) is a novel dynamic and hybrid stabilization option that may be useful in preventing post-laminectomy instability as well as adjacent disc degeneration. Finally, the combined use of dynamic and rigid systems in many patients of this series minimized their biomechanical differences.

Conclusions

Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after a 5–8-year follow-up period, and the ASD incidence in this study was 4.76%. We are aware that this is a small series, but our long-term follow-up period may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation.

Notes

Conflict of Interest: No authors have any conflict of interest.

References

1. Cheh G, Bridwell KH, Lenke LG, et al. Adjacent segment disease followinglumbar/thoracolumbar fusion with pedicle screw instrumentation: a minimum 5-year follow-up. Spine (Phila Pa 1976) 2007 32:2253–2257. PMID: 17873819.
crossref pmid
2. Dobran M, Nasi D, Brunozzi D, et al. Treatment of unstable thoracolumbar junction fractures: shortsegment pedicle fixation with inclusion of the fracture level versus long-segment instrumentation. Acta Neurochir (Wien) 2016 158:1883–1889. PMID: 27541493.
crossref pmid pdf
3. Kim CH, Chung CK, Jahng TA. Comparisons of outcomes after single or multilevel dynamic stabilization: effects on adjacent segment. J Spinal Disord Tech 2011 24:60–67. PMID: 21270627.
crossref pmid
4. Wu JC, Huang WC, Tsai HW, et al. Pedicle screw loosening in dynamic stabilization: incidence, risk, and outcome in 126 patients. Neurosurg Focus 2011 31:E9.
crossref
5. Hasegawa K, Shimoda H, Kitahara K, Sasaki K, Homma T. What are the reliable radiological indicators of lumbar segmental instability. J Bone Joint Surg Br 2011 93:650–657. PMID: 21511932.
crossref pmid
6. Ko CC, Tsai HW, Huang WC, et al. Screw loosening in the Dynesys stabilization system: radiographic evidence and effect on outcomes. Neurosurg Focus 2010 28:E10.
crossref pmc
7. Kocak T, Cakir B, Reichel H, Mattes T. Screw loosening after posterior dynamic stabilization: review of the literature. Acta Chir Orthop Traumatol Cech 2010 77:134–139. PMID: 20447357.
crossref pmid
8. Bastian L, Lange U, Knop C, Tusch G, Blauth M. Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: a biomechanical study. Eur Spine J 2001 10:295–300. PMID: 11563614.
crossref pmid pmc
9. Chou WY, Hsu CJ, Chang WN, Wong CY. Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients. Arch Orthop Trauma Surg 2002 122:39–43. PMID: 11995879.
crossref pmid
10. Dobran M, Iacoangeli M, Di Somma LG, et al. Neurological outcome in a series of 58 patients operated for traumatic thoracolumbar spinal cord injuries. Surg Neurol Int 2014 5(Suppl 7): S329–S332. PMID: 25289154.
crossref pmid pmc
11. Pfirrmann CW, Metzdorf A, Zanetti M, Hodler J, Boos N. Magnetic resonance classification of lumbar intervertebral disc degeneration. Spine (Phila Pa 1976) 2001 26:1873–1878. PMID: 11568697.
crossref pmid
12. Spallone A. A less-invasive technique for harvesting autologous iliac crest grafts for cervical interbody fusion: technical note. Surg Neurol 2007 67:160–162. PMID: 17254875.
crossref pmid
13. Putzier M, Hoff E, Tohtz S, Gross C, Perka C, Strube P. Dynamic stabilization adjacent to single-level fusion: part II. No clinical benefit for asymptomatic, initially degenerated adjacent segments after 6 years followup. Eur Spine J 2010 19:2181–2189. PMID: 20632044.
crossref pmid pmc
14. Tai CL, Hsieh PH, Chen WP, Chen LH, Chen WJ, Lai PL. Biomechanical comparison of lumbar spine instability between laminectomy and bilateral laminotomy for spinal stenosis syndrome: an experimental study in porcine model. BMC Musculoskelet Disord 2008 9:84PMID: 18547409.
crossref pmid pmc pdf
15. Maserati MB, Tormenti MJ, Panczykowski DM, Bonfield CM, Gerszten PC. The use of a hybrid dynamic stabilization and fusion system in the lumbar spine: preliminary experience. Neurosurg Focus 2010 28:E2.
crossref
16. Tamburrelli FC, Proietti L, Logroscino CA. Critical analysis of lumbar interspinous devices failures: a retrospective study. Eur Spine J 2011 20(Suppl 1): S27–S35. PMID: 21404029.
crossref pmid
17. Bono CM, Lee CK. Critical analysis of trends in fusion for degenerative disc disease over the past 20 years: influence of technique on fusion rate and clinical outcome. Spine (Phila Pa 1976) 2004 29:455–463. PMID: 15094543.
crossref pmid
18. Dobran M, Iacoangeli M, Nasi D, et al. Posterior titanium screw fixation without debridement of infected tissue for the treatment of thoracolumbar spontaneous pyogenic spondylodiscitis. Asian Spine J 2016 10:465–471. PMID: 27340525.
crossref pmid pmc
19. Galbusera F, Bellini CM, Anasetti F, Ciavarro C, Lovi A, Brayda-Bruno M. Rigid and flexible spinal stabilization devices: a biomechanical comparison. Med Eng Phys 2011 33:490–496. PMID: 21177135.
crossref pmid
20. Morishita Y, Ohta H, Naito M, et al. Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization. Eur Spine J 2011 20:1480–1485. PMID: 21301893.
crossref pmid pmc
21. Nakai S, Yoshizawa H, Kobayashi S. Long-term follow-up study of posterior lumbar interbody fusion. J Spinal Disord 1999 12:293–299. PMID: 10451044.
crossref pmid
22. Pan A, Hai Y, Yang J, Zhou L, Chen X, Guo H. Adjacent segment degeneration after lumbar spinal fusion compared with motion-preservation procedures: a meta-analysis. Eur Spine J 2016 25:1522–1532. PMID: 26968875.
crossref pmid pdf
23. Richolt J, Rauschmann M. Pedicle screw-based systems for dynamic stabilization: an insight into the philosophy, technique, indications and success of these systems. Orthopade 2010 39:602–608. PMID: 20505924.
crossref pmid
Fig. 1

(A, B) The Flex+TM device (SpineVision, Antony, France) is a rod that can be used with pedicle screws. It is made up of the rigid titanium alloy (TA6V) at extremities and a dynamic part consisting of a twisted titanium alloy cable over-molded with polycarbonate urethane polymer.

asj-12-263-g001.jpg
Fig. 2

Pre-, intra-, and postoperative imaging of patient 21 of Table 1. This patient was a 74-year-old female with 6 months??history of L5 bilateral radiculopathy and claudication. (A) Preoperative sagittal T2-weighted magnetic resonance imaging showing L4–S1 stenosis with the L4–L5 pathological disc (Pfirmann 4) at the same level as that of the planned laminectomy with first-grade spondylolisthesis and a caudal pathological disc (Pfirmann 4). (B) Intraoperative picture of a three-level stabilization (L4–L5–S1) with the hybrid device (rigid L4–L5 and dynamic L5–S1). (C) Postoperative computed tomography with sagittal reconstruction demonstrating the correct positioning of the device and dynamic segment of stabilization (white arrow).

asj-12-263-g002.jpg
Fig. 3

(A) After 5 years, the patient presented a new onset of radiculopathy and claudication, and magnetic resonance imaging showed an adjacent segment degeneration with stenosis one level above the stabilization. (B) Postoperative X-ray. The patient was re-operated with extension of laminectomy on the above levels and six rigid level stabilization (L1–S1).

asj-12-263-g003.jpg
Table 1

Summary of patients' details

asj-12-263-i001.jpg

F, female; M, male.

Table 2

Pre- and postoperative and last follow-up VAS and ODI scores and incidences of ASD in all the 21 patients

asj-12-263-i002.jpg

VAS, Visual Analog Scale score; ODI, Oswestry Disability Index score; ASD, adjacent segment degeneration.

a)VAS and ODI scores in 19 of 21 patients (exclusion of two patients: one dead and one with ASD).

Table 3

Pre- and postoperative VAS and ODI scores in group A (dynamic device)

asj-12-263-i003.jpg

VAS, Visual Analog Scale score; ODI, Oswestry Disability Index score.

Table 4

Pre- and postoperative VAS and ODI scores in group B (hybrid device)

asj-12-263-i004.jpg

VAS, Visual Analog Scale score; ODI, Oswestry Disability Index score.

TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 3 Crossref
  • 4 Scopus
  • 3,852 View
  • 64 Download
Related articles in ASJ


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine
88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
Tel: +82-2-3010-3530    Fax: +82-2-3010-8555    E-mail: asianspinejournal@gmail.com                
Korean Society of Spine Surgery
27, Dongguk-ro, Ilsandong-gu, Goyang-si 10326, Korea
Tel: +82-31-966-3413    Fax: +82-2-831-3414    E-mail: office@spine.or.kr                

Copyright © 2024 by Korean Society of Spine Surgery.

Developed in M2PI

Close layer
prev next