Dear Editor,
We read with great interest the article by Kimchi et al. [
1], “Artificial intelligence–based detection of acute postoperative airway complications following anterior cervical spine surgery: a retrospective imaging evaluation.” The authors developed an artificial intelligence (AI) model to identify postoperative airway compromise after anterior cervical spine surgery using routine postoperative imaging. This is a clinically important target because airway compromise is uncommon but potentially catastrophic; a recent meta-analysis of 42 studies involving 960,092 patients undergoing anterior cervical discectomy and fusion estimated an incidence of 0.78% [
2].
We would appreciate clarification regarding the derivation of the reported model-performance metrics. The authors report a positive predictive value (PPV) of 0.98, negative predictive value (NPV) of 0.90, sensitivity of 0.91, and specificity of 0.99. However, the AI dataset contained only nine patients with airway obstruction and 411 controls, and the composition of the 84-patient testing set was not reported. At the prevalence observed in the overall cohort (11/795; 1.3%), a sensitivity of 0.91 and specificity of 0.99 would correspond to an expected PPV of approximately 56% and an NPV of 99.9%. Even at the prevalence of the AI dataset (9/420; 2.1%), the corresponding values would be approximately 67% and 99.8%, respectively. Unless the reported metrics represent averages across differently composed cross-validation folds or were calculated after class rebalancing, the four values are difficult to reconcile as estimates derived from a single evaluation population.
Fig. 3 of the article by Kimchi et al. [
1] appears to present a normalized rather than count-based confusion matrix. Providing the raw numbers of true-positive, false-positive, true-negative, and false-negative classifications in the 84-patient testing set, together with its event prevalence, would allow readers to reproduce the reported metrics. This is particularly important in a severely imbalanced classification problem, in which precision-recall performance can be more informative for evaluating positive predictions [
3]. Contemporary TRIPOD+AI guidance similarly emphasizes transparent reporting of evaluation data and model performance to facilitate appraisal and implementation [
4].
The clinical interpretation of the reported NPV also deserves caution. The authors suggest that the model’s “high NPV” may help avoid unnecessary wound reopening or intensive care unit admission. Yet predictive values are prevalence-dependent, and an NPV obtained from an enriched or rebalanced evaluation sample cannot be directly transported to routine clinical practice.
Finally, two of the 11 patients with airway obstruction required emergency wound opening before postoperative imaging and were therefore excluded from the AI dataset. Thus, the model was evaluated only in patients who remained sufficiently stable to undergo routine postoperative imaging. This limitation is acknowledged by the authors, but it remains important when defining the population in which the tool may safely support clinical decision-making.
We believe that reporting the raw testing-set confusion matrix, clarifying whether the performance metrics were fold-averaged or calculated from a single held-out testing set, and performing external evaluation under real-world event prevalence would substantially strengthen this promising work.