Sagittal Section Hounsfield Units of the Upper Instrumented Vertebrae as a Predictor of Proximal Junctional Vertebral Fractures Following Adult Spinal Deformity Surgery
Article information
Abstract
Study Design
A retrospective observational study.
Purpose
This study aimed to determine an accurate and convenient screening method for predicting proximal junctional fractures (PJFr) following surgery for adult spinal deformity (ASD) using computed tomography (CT)-based measurement of Hounsfield units (HUs).
Overview of Literature
CT-based measurement of HUs is an alternative tool for assessing bone mineral density. However, the optimal method for predicting adjacent vertebral fractures following spinal fusion using HUs remains unclear.
Methods
This retrospective observational study included 42 patients who underwent reconstructive surgery for ASD. Elliptical regions of interest (ROIs) on the axial section and rectangular ROIs on the sagittal section were placed at the upper instrumented vertebrae (UIV), UIV+1, and UIV+2. In addition, the HU value of the L2 vertebra was used as the representative.
Results
PJFr occurred in 28.6% of patients within 2 years following surgery. The HU values obtained from the axial sections of L2, UIV, UIV+1, and UIV+2 were not significantly associated with the incidence of PJFr within 2 years, except for the ROI set in the lower region of the L2 vertebra. However, the HU value of the anterior third of the UIV in the sagittal section was significantly lower in the PJFr group than in the nonPJFr group (87.0 vs. 160.3, p=0.001). A UIV HU value of <100 was associated with a higher incidence of PJFr than an HU vaue of >100 (p<0.05).
Conclusions
Measurements of HU in the anterior one-third of the UIV in the sagittal section demonstrated predictive ability for PJFr following ASD surgery. A UIV HU value of <100 emerged as a risk factor for PJFr.
Introduction
Symptomatic proximal junctional kyphosis (PJK), also referred to as proximal junctional failure, may require additional surgical intervention following corrective surgery for adult spinal deformity (ASD) [1]. Proximal junctional fractures (PJFr) are the most common cause of PJK and have been observed in approximately 51% of patients with PJK [2]. Risk factors for PJFr include high body mass index, advanced age, presence of osteoporosis, choice of the upper instrumented vertebra (UIV), and spinopelvic parameters [3]. Among these risk factors, low bone mineral density (BMD) and osteoporosis are considered significant contributors.
Currently, dual-energy X-ray absorptiometry (DEXA) is the gold standard for assessing BMD and diagnosing osteoporosis [4]. However, DEXA may yield inaccurate results in the diagnosis of osteoporosis. Factors such as sclerotic lesions, scoliosis, spinal degeneration, vertebral fractures, and abdominal aortic calcification can lead to an overestimation of BMD when assessed using DEXA.
Recently, there have been suggestions to use computed tomography (CT) and analyze Hounsfield unit (HU) measurements as supplementary methods for assessing BMD. Unlike DEXA, CT is not affected by measurement errors caused by degenerative changes, and a positive correlation between CT HU values and DEXA BMD was established [4]. HU measurements are also correlated with future osteoporotic fracture risk, cage subsidence following interbody fusion, pedicle screw loosening, and symptomatic pseudarthrosis following posterolateral fusion [5–10]. Considering these findings, spine experts recommended that patients aged ≥65 years, as well as those aged <65 years with specific risk factors, should undergo a comprehensive bone health assessment that includes CT-based measurement of the HU value [11,12].
The association of HU with the development of PJK or mechanical complications has been suggested [13–17]. However, the optimal method for measuring HU values to predict postoperative PJFr remains unknown. Thus, whether the use of the HU value of the UIV or representative HU of vertebral bodies in the lumbar spine, such as L2, like in DEXA, is more accurate remains unclear. This study aimed to analyze HU values in different vertebrae and regions of interest (ROI) within thoracolumbar CT images to propose a more precise and convenient screening method for predicting PJFr following ASD surgery.
Materials and Methods
1. Patients
From January 2013 to August 2019, 120 patients aged >50 years who underwent spinal fusion and were diagnosed with ASD were reviewed. ASD was defined as the presence of at least one of the following: sagittal vertical axis (SVA) >50 mm, coronal Cobb angle >20°, pelvic tilt (PT) >25°, or thoracic kyphosis (TK) >60° [18,19]. Patients who underwent instrumentation from the UIV between T7 and L2, along with sacral fusion of the lowest instrumented vertebrae, with or without iliac fixation, were enrolled. Patients were required to have a minimum follow-up of 2 years. Patients with a history of two lumbar spine surgeries were excluded (Fig. 1).
This study was approved by the ethics committee of the authors’ affiliated institutions and was conducted in compliance with the principles of the Declaration of Helsinki. Informed consent was waived because of the retrospective design.
2. Radiographic assessment
Lateral spine radiographs were obtained at baseline (before surgery), 3 and 6 months after surgery, and annually thereafter until the final follow-up. These radiographs were used to evaluate morphometric vertebral fractures. To determine the anterior, posterior, and mid-height, six points were marked on each vertebra. PJFr were defined as new fractures occurring at the UIV, UIV+1, or UIV+2 levels, with a reduction in vertebral height of >20% (minimum of 4 mm) from baseline measurements [20]. Acute vertebral fractures were determined using magnetic resonance imaging, which showed characteristic patterns of low-intensity signal changes on T1-weighted images and high-intensity signal changes on T2-weighted images [21].
In this study, various radiographic parameters were assessed, including PT, lumbar lordosis (LL) from L1 to S1, pelvic incidence (PI), TK between T4 and T12, SVA, LL from L4 to S1, and global tilt [22]. The proximal junctional angle (PJA), UIV slope (angle between the superior endplate of the UIV and the horizontal plane), UIV inclination (angle between a line crossing the center of the vertebral body from UIV-2 to UIV and the vertical line), and UIV tilt (angle between a line parallel to the upper endplate of the upper instrumented vertebra and the horizontal line) were also measured [23–25]. Moreover, the occupancy rate of the pedicle screw was evaluated as previously outlined [26]. The angle of the UIV pedicle screw was determined by the orientation of the screw shaft relative to the superior vertebral endplate [27]. A screw was considered caudally directed if it was angled >2° downward from the superior endplate.
Furthermore, patients were categorized according to Roussouly’s newly proposed classification for categorizing the progression of asymptomatic spinal typologies under degenerative conditions based on the SS and LL contours [28]. Patients were also grouped according to the degree of LL correction relative to PI by adjusting for age, which uses the following formula [29,30]: (age-adjusted ideal PI–LL)–(postoperative PI–LL). The three groups were as follows: group U (undercorrection; <10°), group I (ideal correction; −l10° to 10°), and group O (overcorrection; >10°). Following the calculation of the five components of the Global Alignment and Proportion (GAP) score, patients were further classified into proportionate, moderately disproportionate, and severely disproportionate groups [22].
3. Computed tomography assessment
CT was performed using different multidetector scanners (Siemens SOMATOM Sensation Open [Siemens Healthineers AG, Forchheim, Germany], Canon Medical Aquilion PRIME [Canon Medical System Corp., Tochigi, Japan], Philips Ingenuity Core 64 slice [Philips, Amsterdam, The Netherlands]) with a consistent peak voltage of 120 kV and variable protocol-specific tube current (mA) settings. Although the kV settings strongly affected the HU values of the bone, the mA settings only influenced the noise levels [31].
To assess osteoporosis and bone fragility using the HU values of the vertebral body, different methods for ROI selection were employed. ROIs are typically set on an axial slice of the L2 vertebral body. Because HU values varied across different heights within the same vertebral body, elliptical ROIs were placed on the upper, middle, and lower thirds of the vertebral body to measure HU values. The HU values were also measured at the UIV, UIV+1, and UIV+2 levels. The average and lowest values were calculated, and their relationship with the incidence of PJFr within 2 years was investigated.
The HU values of the anterior third of the vertebral body (UIV, UIV+1, and UIV+2) were also measured in the median and adjacent left and right planes on sagittal CT images. A rectangular ROI was manually placed, and the lowest HU value of the vertebral body was selected while avoiding areas with cortical bone or severe sclerotic abnormalities (Fig. 2) [10].

Demonstration of Hounsfield unit (HU) measurement. (A) HU value in axial plane. HU values of upper instrumented vertebra (UIV), UIV+1, UIV+2, and L2 were measured in axial plane, by placing the elliptical regions of interests (ROIs) at the upper 1/3 level, the middle, and lower 1/3 levels. (B) The HU value of the anterior 1/3 of the vertebral body was measured in the midsagittal plane by manually placing rectangle ROIs.
4. Statistical analyses
Statistical analyses were performed using JMP Pro ver. 15.0 (SAS Institute Inc., Cary, NC, USA) or R ver. 4.3.2 (The R Foundation for Statistical Computing, Vienna, Austria) with a two-tailed paired t-test (two conditions). Kaplan-Meier plots were used to illustrate fracture-free survival for the participants according to their HU values. The log-rank test was used to evaluate the statistical significance of the differences between the groups. The time to PJFr was analyzed using multivariate Cox proportional hazards modeling. Statistical significance was set at p<0.05.
Results
The study included 42 patients with a mean age of 69.2±9.1 years. Overall, 83.3% of the patients were female, and 23.8% had a history of lumbar surgery. The UIV levels were distributed as follows: L2, T10, and T9. Iliac fixation was performed in 76.2% of the patients. The characteristics of the participants are provided in Table 1.
Twelve patients experienced PJFr within 2 years following surgery. No significant differences in age, sex, history of previous surgery, UIV level, history of lumbar surgery, or body mass index were found between the PJFr and nonPJFr groups. Pre- and postoperative radiographic parameters are shown in Table 2. No statistically significant differences were found in the preoperative LL, PI, PI–LL, PT, SVA, or global tilt between the PJFr and nonPJFr groups. No significant differences in Roussouly classification, GAP classification, PJA, UIV tilt angle, UIV slope, or UIV inclination were noted between the two groups. Similarly, no significant differences in postoperative LL, PT, PI–LL, age-adjusted PI–LL, SVA, global tilt, or screw occupancy ratio were found between the two groups. The proportion of the caudally directed screws was significantly higher in the PJFr group than in the nonPJFr group (p<0.01).
The ROI was set on the axial plane of L2 as a representative. HU values in the axial plane differed depending on the vertebral body level. In the lower slice, the L2 HU values were significantly lower in the PJFr group than in the nonPJFr group (p=0.01). However, no significant differences were observed in the other ROIs (Table 3).

Comparison of Hounsfield unit values between patients with and those without proximal junctional fracture
Furthermore, ROIs were set in the axial plane of the UIV. Elliptical ROIs were placed on the upper, middle, and lower thirds of the vertebral body, and the minimum and average HU values were calculated. No statistical difference was found in the HU values between the PJFr and nonPJFr groups (Table 3). In addition, the average or minimum HU values of the axial slice in the UIV did not differ between the PJFr and nonPJFr groups. When the ROI was set in the axial plane of UIV+1 or UIV+2, the HU values in each section were not significantly different. No differences were observed in the average or minimum HU values in the axial section of UIV+1 and UIV+2.
The HU value of the anterior third of the UIV was significantly lower in the PJFr group than in the nonPJFr group (Table 3). The mean or minimum HU values of the anterior one-third of the sagittal section of the UIV, UIV+1, and UIV+2 groups were significantly lower in the PJFr group than in the nonPJFr group.
Receiver operating characteristic curves were generated for the HU values in the sagittal plane of each patient to predict vertebral fractures within 2 years following surgery (Fig. 3A–C). The area under the curve was the largest in the order of UIV, mean HU value, and minimum HU value in the sagittal section. These findings suggest that the HU value of the UIV in the sagittal plane provides a more accurate prediction of future PJFr.

(A) Receiver operating curves (ROC) of Hounsfield unit (HU) value in upper instrumented vertebra (UIV) from sagittal plane against proximal junctional fracture (PJFr) within 2 years of surgery. Area under the curve (AUC) was calculated. (B) ROC of average HU value from UIV, UIV+1, and UIV+2 in the sagittal plane. (C) ROC of minimum HU value from UIV, UIV+1, and UIV+2 in the sagittal section. (D) Odds ratio for PJFr within 2 years analyzed by multivariate logistic analysis using HU value in UIV and UIV screw direction as covariate. (E) Kaplan-Meier curves of PJFr-free survival for patients, grouped by vertebral attenuation threshold of 100 HU in sagittal section of UIV. (F) Survival curves adjusted by the UIV screw direction.
At a cutoff value of 100.1, the sensitivity and specificity were 1.0 and 0.39, respectively. Therefore, a cutoff value of 100 was chosen for this study. Regarding postoperative spinal parameters, a significant difference was observed in the direction of the UIV screw between the PJFr and nonPJFr groups (Table 2). Multivariate logistic regression analysis showed that a UIV HU value of <100 was a significant risk factor for the occurrence of PJFr within 2 years (Fig. 3D). Accordingly, patients with a UIV HU value of <100 experienced a higher incidence of PJFr than those with a value of >100 (p<0.05) (Fig. 3E), and the same result was obtained when the direction of the UIV screw was analyzed as a covariate (Fig. 3F).
Discussion
In this study, HU values on sagittal images were more effective than those on vertebral axial images in predicting PJFr. Moreover, PJFr could be predicted by assessing the HU values of the UIV alone, without measuring UIV, UIV+1, and UIV+2.
Assessing bone quality before surgical correction of ASD is crucial because of the potential complications associated with PJFr in both the patients and treatment team. DEXA is considered the gold standard for BMD assessment. However, DEXA is not optimal for assessing BMD in the presence of degenerative changes or spinal deformities. In addition, DEXA is not specifically designed for ASD surgery in terms of measurement sites and thresholds because the thoracic spine is not a standard area for DEXA. However, HU values can be used to estimate regional bone strength. For example, the HU value of the screw trajectory can be measured, and the cortical bone trajectory was found to have significantly higher CT values than the conventional pedicle screw trajectory [32]. Another study demonstrated a correlation between HU values and pedicle screw insertion torque [33]. Similarly, CT-based HU values can directly evaluate the BMD of the anterior portion of the UIV, which is susceptible to collapse.
The present study set a rectangular ROI in the anterior one-third of the vertebral body, whereas previous studies often used an elliptical ROI encompassing the entire vertebral body. Studies have reported spatial heterogeneity in the trabecular bone density within the vertebra [34–36]. To minimize vertebral heterogeneity, recent reports evaluating the risk of proximal junctional failure adopted a method to calculate the average HU values by setting the elliptical ROI immediately inferior to the superior end plate, middle of the vertebral body, and superior to the inferior endplate [13–15,17]. Wedge fractures can be associated with low BMD in the superior anterior region [37]. Therefore, evaluating the HU value in the anterior one-third of the vertebral body is reasonable, although few studies have demonstrated the usefulness of HU values measured in the anterior third of the sagittal plane compared with those in the axial plane [10]. In this study, we could not find a difference in the averaged HU value of UIV, UIV+1, or UIV+2. Given the small number of cases in this study, the average HU value of the axial section may not have shown a statistically significant difference. However, measuring the HU value at the sagittal section may be more sensitive to predict PJFr.
In this study, DEXA-derived BMD data were unavailable. Previous studies have focused on the lumbar spine and established thresholds, such as 135 HU for osteopenic spines, 120 HU for pedicle screw loosening, 110 HU for osteoporotic spines, and 90 HU for vertebral fracture [4,38,39]. Although these studies have evaluated HU values using axial slices, our cutoff level of 100 was similar to that of previous reports.
Previously, we reported that each vertebral body had different HU values in the sagittal plane depending on the level [10]. Furthermore, lower HU thresholds are associated with higher specificity and lower sensitivity for detecting osteoporosis and predicting fractures, whereas higher thresholds are associated with lower specificity and higher sensitivity. In addition, the optimal thresholds for estimating the PJFr risk using the HU values of representative vertebral bodies may differ from those for predicting the PJFr risk in individual vertebrae, considering the spinal alignment, fixed levels, and fragile sites within the vertebral bodies. Optimal thresholds for each application must be proposed.
This study has some limitations. First, BMD was not measured using DEXA, as previously mentioned, and the corresponding BMD values for specific HU values remain unknown. Second, the relationship between the effects of osteoporotic drugs and HU values was not investigated. Further studies are needed to assess the preventive effects of antiosteoporotic drugs, braces, and changes in surgical strategies, which may influence HU values. Third, the number of patients was limited. PJFr has multifactorial causes and is affected by various factors, including preoperative and postoperative spinal parameters and their changes, UIV fixation method, osteoporosis, and other factors. In this study, no difference in spinal parameters was noted between the PJFr and nonPJFr groups, and the contribution of each risk factor to PJFr could not be compared.
Conclusions
CT-based measurement of the HU value in the anterior one-third of the vertebral body was predictive of the PJFr risk following ASD surgery. The HU values obtained from the sagittal images more effectively predict PJFr than the values obtained from the axial images. Specifically, a UIV HU value of <100 was identified as a significant risk factor for PJFr.
Notes
Conflict of Interest
No potential conflict of interest relevant to this article was reported.
Author Contributions
Conceptualization: Koichi Murata. Methodology: Koichi Murata. Data curation: Koichi Murata. Investigation: Bungo Otsuki, Takayoshi Shimizu, Takashi Sono, Shunsuke Fujibayashi. Writing–original draft: Koichi Murata. Writing–review & editing: Bungo Otsuki, Takayoshi Shimizu, Takashi Sono, Shunsuke Fujibayashi, Shuichi Matsuda. Supervision: Shuichi Matsuda. Final approval of the manuscript: all authors.