Asian Spine J Search

CLOSE


Asian Spine J > Volume 15(1); 2021 > Article
Shah, Gadiya, Shah, Vyas, Patel, Bhojraj, and Nene: Does Three-Dimensional Printed Patient-Specific Templates Add Benefit in Revision Surgeries for Complex Pediatric Kyphoscoliosis Deformity with Sublaminar Wires in Situ? A Clinical Study

Abstract

Study Design

Case-control study.

Purpose

To evaluate the accuracy of three-dimensional (3D) printed patient-specific templates (PSTs) for placement of pedicle screws (PAs) in patients undergoing revision surgeries for complex kyphoscoliosis deformity with sublaminar wires in situ.

Overview of Literature

Revision kyphoscoliosis correction surgery in pediatric patients is a challenging task for the treating surgeon. In patients with sublaminar wires in situ, the native anatomical landmarks are obscured, thus making the freehand screw placement technique a highly specialized task. Hence, the concept of using PSTs for insertion of PAs in such surgeries is always intriguing and attractive.

Methods

Five consecutive patients undergoing revision deformity correction with sublaminar wires in situ were included in this study. Patients were divided in two groups based on the technique of PA insertion. A total of 91 PAs were inserted using either a freehand technique (group A) or 3D printed templates (group B) (34 vs. 57). The placement of PAs was classified according to a postoperative computed tomography scan using Neo’s classification. Perforation beyond class 2 (>2 mm) was termed as a misplaced screw. The average time required for the insertion of screws was also noted.

Results

Mean age, surgical time, and blood loss were recorded. The change in mean Cobb’s angle in both groups was also recorded. The difference in rates of misplaced screws was noted in group A and group B (36.21% vs. 2.56%); however, the mean number of misplaced PAs per patient in group A and group B was statistically insignificant (6.5±3.54 vs. 4.67±1.53, p=0.4641). The mean time required to insert a single PA was also statistically insignificant (120±28.28 vs. 90±30 seconds, p=0.3456).

Conclusions

Although 3D printed PSTs help to avoid the misplacement of PAs in revision deformity correction surgeries with sublaminar wires in situ, the mean number of misplaced screws per patient using this technique was found to be statistically insignificant when compared with the freehand technique in this study.

Introduction

Deformity correction surgery is regularly performed in pediatric patients, and the outcomes following these surgeries are beneficial in terms of clinical and functional outcomes [1-3]. However, the required revision deformity surgery is challenging for the patient and for the treating physician. Moreover, these surgeries are associated with complications such as wound-healing issues, respiratory complications, pseudo-arthrosis, and instrumentation failure [4-6]. Surgical challenges include poorly developed or ill-defined bony landmarks, a lack of advanced instruments and implants, and the patient’s low medical capability to cope with prolonged surgeries [7]. Implant-related complications often need revision surgery, which is technically demanding and requires a high level of expertise. The incidence rate of revision spinal surgery in pediatric patients is 7.5% to 12.5% [8].
The rate of complications in revision spinal fusion in pediatric patients is higher than in primary spinal fusion (16.7% versus 8.6%) [9]. Most of these complications are implant-related (5.3%) and are often concerned with the malposition of screws because of the distortion of the native anatomical landmarks for pedicle screw insertion [9]. Thus, the concept of using patient-specific and vertebraspecific templates for the insertion of pedicle screws in revision deformity correction surgeries is always intriguing and attractive. Recently, three-dimensional (3D) printing technology has been widely used for manufacturing patient-specific templates, which has been found to be useful for complex spinal deformity surgeries with successful outcomes [10,11]. Many companies in different parts of the world are commercially manufacturing these patient-specific pedicle screw templates (e.g., Firefly; Mighty Oak Medical, Englewood, CO, USA). However, their role in revision spinal surgeries, where they would be most supported, is not reported. Our study highlights the efficacy of 3D printed templates in revision pediatric kyphoscoliosis deformity surgery with previous stainlesssteel implants in situ.

Materials and Methods

This was a prospective study. Five consecutive patients (one male and four females) who had a previous spinal deformity correction using sublaminar wires and a stainless- steel spinal loop rectangle, and who subsequently underwent a revision surgery, were included in this study. All five patients underwent revision deformity correction using the pedicle screws and rod system. The etiology of the deformity was congenital in three of the patients, posttubercular in one patient, and idiopathic in one patient. The type of deformity was scoliosis in three patients, and kyphoscoliosis in the other two patients. In the first two patients, pedicle screws were inserted using the freehand technique (group A), and in the remaining three patients, pedicle screws were inserted using 3D printed templates (group B). Table 1 shows the epidemiological details of all patients. All patients had given their consent and institutional review board approval had been given for this study (Lilavati Hospital and Research Center, Mumbai; IRB approval no., 08/19-3 [b2]).

1. Preoperative planning and making of templates

Preoperatively, all patients underwent plain standing radiographs, spiral computed tomography (CT) scans of the spine with 3D reconstruction, and magnetic resonance imaging scans.
The software used to convert Digital Imaging and Communications in Medicine (DICOM) images to 3D models was the Mimics Innovation Suite (Mimics Medical and 3-Matic Medical 11; Materialise, Leuven, Belgium). The DICOM data of the patient’s CT scan was imported into Mimics Medical 19 (Materialise). On preliminary inspection, it was found to be important to separate the spine from the remnant implant. This was done by first segmenting the bone and implant using appropriate threshold values. Furthermore, manual intervention in segmentation was required to eliminate the artifacts caused by the presence of the stainless-steel implant. The implant and spine were then imported into 3-Matic Medical 11 (Materialise) and were used as base data on which to design pedicle-locating guides for each vertebra, using various computer-aided design tools available in the software. A team comprising a biomedical engineer and a surgeon differentiated the metal artifacts and the bone defects so as to make templates that had the maximum potential bone contact surface. The final 3D printed model of the spine and the design of the templates are shown in Fig. 1.

2. Surgical procedure

Two senior spinal surgeons and the same surgical team performed all the surgeries. All patients underwent a single-stage removal of the sublaminar wires and spinal rectangle and revision deformity correction using the standard titanium pedicle screws and rod system. Spinal exposure was achieved taking care to remove all soft tissue and to preserve bone, such that the templates would fit snuggly.
The removal of the sublaminar wires/spinal loop rectangle was done carefully, so bony landmarks were not affected. The 3D printed templates were then used for inserting the pedicle screws in group B patients. Spinal cord monitoring was used in all patients during surgery. No patient had intraoperative signal changes, either motor evoked potentials or somatosensory evoked potentials, during surgery. No patient had neurological worsening postoperatively (Fig. 2).

3. Postoperative course

Following surgery patients were mobilized out of bed depending on their pain tolerance. No brace support was used. The CT scans were performed in the postoperative period at first follow-up (at 3 months) in all patients to study the placement of the pedicle screws. A screw was designated as a misplaced screw if it was found to be perforating the respective pedicle (a breach in either the superior, inferior, medial, or lateral cortex) beyond 2 mm as described by Neo et al. [12].

Results

The mean age of the patients in the study group was 12.2±2.2 years. The mean surgical time was 238±57.62 minutes. The mean blood loss was 610±277.04 mL. Of the total 91 pedicle screws, 34 pedicle screws were inserted using the freehand technique, and 57 pedicle screws were inserted using 3D printed templates. The mean preoperative Cobb’s angle in group A was 54°±19.8°, while that in group B was 79.33°±13.61°. The mean postoperative Cobb’s angle in group A was 27°±4.4°, while that in group B was 31.33°±10.26°. The total number of misplaced pedicle screws in group A was 13, while that in group B was 14 (Table 1). The rate of misplaced screws in group A was 36.21%, while that in group B was 24.56% (Table 1). The mean number of misplaced pedicle screws per patient in group A was 6.5±3.54, while that in group B was 4.67±1.53; this was statistically insignificant (p=0.4641). The mean time required to insert a single pedicle screw in group A was 120±28.28 seconds, while that in group B was 90±30 seconds; this was statistically insignificant (p=0.345) (Table 2).

Discussion

Traditionally, pedicle screws are inserted in the lumbar spine using a freehand technique; however, pedicle screw insertion in the thoracic spine is more challenging due to the complex native anatomy [13,14]. Insertion of pedicle screws by this method is based on preoperative radiology, the intraoperative native bony anatomy, and the tactile feedback of the surgeon. Placement of pedicle screws in kyphoscoliosis correction surgery requires technical expertise owing to the vertebral rotation and associated congenital bony malformations. Rigid deformities are often associated with anomalies of the thoracic spine pedicle [15]. The risk of injury to the spinal cord increases on the concave side of the deformity because the pedicles are thinner, sclerotic, and dysplastic and the spinal cord lies in direct contact with the medial wall of the concave pedicles. The rate of screw malposition in scoliosis surgery is reported as being 4.2% to 15% [16]. These problems are multiplied in the pediatric population due to difficulties in instrumentation, growth of the vertebral column, and lung development.
To address this problem, various techniques of safe pedicle screw placement have been described in the literature, including intraoperative fluoroscopy, computer-assisted navigation based on the preoperative CT scan, O-arm-based navigation, robotic-assisted pedicle screw placement, use of a PediGuard, and use of 3D printed templates [17-22].
Various authors have previously reported on use of navigation based on preoperative CT scans for safe placement of pedicle screws in deformity correction of the spine [23,24]. The pedicle screw misplacement with this technique is reported as being between 1.8% and 11.4% [23,24]. In patients undergoing revision deformity correction with sublaminar wires and rectangle loop in situ, there are many metal artifacts causing differences in anatomical relationships, as determined by the preoperative CT scan and intraoperative findings. Also, selecting starting points for pedicle screw placement on 3D reconstruction of the preoperative CT scan is not possible in these patients.
O-arm-based navigation has an advantage over the previous technique as it provides an intraoperative CT scan of the patient for safe placement of the pedicle screws. The operating surgeon does not need to rely on the preoperative CT scan, which may be obscured with metal artifacts that make the bony landmarks difficult to identify. However, intraoperative CT scans are associated with increased radiation exposure, both to the surgical team and the patient [25]. Moreover, the cost of equipment and space occupied by the O-arm is relatively high when compared with CT-based navigation. The rate of pedicle screw misplacement in scoliosis surgery using O-arm navigation has been reported to be approximately 3.1% [18].
Recently, many studies have reported the use of robotics in spinal surgery for safe placement of pedicle screws [19,26,27]. However, their use in scoliosis surgery is scarcely described in the literature [19,27]. In adolescent idiopathic scoliosis, the rate of misplacement in pedicle screws with robotic-assisted placement has been reported to be 7.2% [19]. However, the use of robotics for placement of pedicle screws cannot be universalized due to the cost constraints, especially in developing countries, and the complexity and time involved in registering the data and operating it, and an associated steep learning curve. Also, the space occupied by the robot in the operating room is a concern.
With the advancement in technology, the role of 3D printing in preoperative planning and execution of complex spinal surgery has been increasingly explored in the last two decades [28]. Application of 3D printing (additive manufacturing) to manufacture the custom-made templates for insertion of the pedicle screws in complex spinal surgeries is well reported in the literature [29,30]. Using patient-specific data to create templates that can be used during surgery reduces the risk associated with misplaced pedicle screws. The 3D printed templates provide simple, convenient, low cost, and complex-equipment-free alternatives to increase the accuracy of pedicle screw placement in complex spinal surgeries [29]. The advantages can also be realized for insertion of screws in patients undergoing revision surgery for deformity correction who have sublaminar wires and a stainless-steel rectangle loop in situ.
Takemoto et al. [31] evaluated the efficacy of placement of a thoracic pedicle screw using patient-specific templates made by 3D printing technology. Out of 40 patients, 36 had scoliosis as the primary indication of surgery. The authors reported a 98.4% success rate for placement of pedicle screws using the patient-specific templates in scoliosis surgery. However, none of the patients in the study group had revision deformity correction.
Liu et al. [32] compared the freehand technique of pedicle screw insertion with the technique utilizing the 3D printed templates in ten patients who were undergoing deformity correction surgery for severe rigid scoliosis. The success rate was 93.8% for pedicle screw placement using 3D printed drill guides, while it was 78.8% for pedicle screw insertion using the freehand technique. No screw-related complications were reported. However, in this study group, none of the patients were operated on previously for deformity correction.
The rate of misplaced pedicle screws in our study using the freehand technique was 36.21%, which was very similar to the rate described in previous studies. The rate of misplacement of pedicle screws using 3D printed templates in our study group was 24.56%. The higher rate of pedicle screw misplacement in the present study can be attributed to the metal artifacts/bone defects causing difficulty in making base plates for the 3D printed templates. This cohort poses special challenges for making 3D printed templates and requires a skilled biomedical engineer and an experienced surgeon to manually segregate the metal artifacts and previous bone defects based on the preoperative CT scan and to make templates with maximum contact of the base plate with the remnant bone.
Our study had few limitations. It had a small sample size; however, this can be attributed to revision of sublaminar wires with pedicle screws being a rare scenario. We could not compare apical screws, or screws near previous bone defects, with relatively easier lumbar screws, or screws near virgin spine, due to the small sample size. We believe that 3D printed templates are a useful tool in the pediatric spinal deformity surgeon’s armory for safe pedicle screw placement in primary complex deformity surgeries. Its potential in revision deformity surgeries with previous stainless-steel implants in situ seems like a possible exciting advance.

Conclusions

Pedicle screw fixation in revision surgeries for complex pediatric kyphoscoliosis deformity (especially with sublaminar wires in situ) poses a substantial challenge for the operating surgeon. The rate of misplaced pedicle screws (in this subset of the population) in the present study with the freehand technique is clinically higher than that compared with use of 3D printed patient-specific pedicle screw templates; however, this was not statistically significant. This novel technique of using 3D printed pedicle screw templates has advantages in revision surgeries of complex pediatric kyphoscoliosis deformity. With further improvement in manufacturing technology of these templates, the rate of pedicle screw misplacement will definitely reduce further in this particular subset of patients.

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Fig. 1.
(A) 3D printed biomodel of the spine and spinal rectangle loop with sublaminar wires. (B) 3D printed pedicle screw templates. 3D, three-dimensional.
asj-2019-0021f1.jpg
Fig. 2.
(A, B) Preoperative radiograph (AP and lateral) showing kyphoscoliosis deformity with broken implants (sublaminar wires and spinal loop rectangle in situ). (C, D) Intraoperative images showing use of three-dimensional printed templates for pedicle screw insertion. (E, F) Postoperative radiograph (AP and lateral view). (G–I) Postoperative computed tomography scan showing pedicle screws. AP, anteriorposterior.
asj-2019-0021f2.jpg
Table 1.
Epidemiological details of patients
No. Age (yr) Sex Etiology Surgical time (min) Blood loss (mL) Screw insertion technique Cobb’s angle (°)
No. of pedicle screws inserted Well placed screws Misplaced screws Average time required for insertion of 1 screw (sec)
Preoperative Postoperative
1 10 F Congenital 200 350 Group B 90 40 15 12 3 60
2 11 M Post Koch’s 240 600 Group B 84 34 17 12 5 90
3 12 F Congenital 180 350 Group B 64 20 25 19 6 120
4 16 F Congenital 240 750 Group A 40 30 14 10 4 100
5 12 F Idiopathic 330 1,000 Group A 68 24 20 11 9 140

F, female; M, male.

Table 2.
Details of pedicle screws in both groups
Variable Group A Group B p-value
Average time required to insert 1 screw (sec) 120±28.28 90±30 0.3456a)
No. of misplaced screws 6.50±3.54 4.67±1.53 0.4641b)
No. of pedicle screws inserted 17±4.24 19±5.29 0.6889b)

Values are presented as mean±standard deviation.

a) Calculated using t -test.

b) Calculated using chi-square test.

References

1. Fu KM, Smith JS, Polly DW, et al. Morbidity and mortality associated with spinal surgery in children: a review of the Scoliosis Research Society morbidity and mortality database. J Neurosurg Pediatr 2011;7:37–41.
crossref pmid
2. Helenius I, Remes V, Lamberg T, Schlenzka D, Poussa M. Long-term health-related quality of life after surgery for adolescent idiopathic scoliosis and spondylolisthesis. J Bone Joint Surg Am 2008;90:1231–9.
crossref pmid
3. Kepler CK, Meredith DS, Green DW, Widmann RF. Long-term outcomes after posterior spine fusion for adolescent idiopathic scoliosis. Curr Opin Pediatr 2012;24:68–75.
crossref pmid
4. Dede O, Yazici M. Revision surgery for pediatric spine deformity: corrective osteotomies. J Pediatr Orthop 2014;34 Suppl 1:S6–10.
crossref pmid
5. Kim HJ, Cunningham ME, Boachie-Adjei O. Revision spine surgery to manage pediatric deformity. J Am Acad Orthop Surg 2010;18:739–48.
crossref pmid
6. Yagi M, King AB, Kim HJ, Cunningham ME, Boachie-Adjei O. Outcome of revision surgery in pediatric spine deformity patients. Spine Deform 2013;1:59–67.
crossref pmid
7. Ramo BA, Richards BS. Repeat surgical interventions following “definitive” instrumentation and fusion for idiopathic scoliosis: five-year update on a previously published cohort. Spine (Phila Pa 1976) 2012;37:1211–7.
crossref pmid
8. Richards BS, Hasley BP, Casey VF. Repeat surgical interventions following “definitive” instrumentation and fusion for idiopathic scoliosis. Spine (Phila Pa 1976) 2006;31:3018–26.
crossref pmid
9. De la Garza Ramos R, Goodwin CR, Purvis T, Karikari IO, Samdani AF, Sciubba DM. Primary versus revision spinal fusion in children: an analysis of 74,525 cases from the nationwide inpatient sample. Spine (Phila Pa 1976) 2017;42:E660–5.
crossref pmid
10. Mao K, Wang Y, Xiao S, et al. Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study. Eur Spine J 2010;19:797–802.
crossref pmid pmc pdf
11. Wu ZX, Huang LY, Sang HX, et al. Accuracy and safety assessment of pedicle screw placement using the rapid prototyping technique in severe congenital scoliosis. J Spinal Disord Tech 2011;24:444–50.
crossref pmid
12. Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 2005;30:2800–5.
crossref pmid
13. Motiei-Langroudi R, Sadeghian H. Assessment of pedicle screw placement accuracy in thoracolumbosacral spine using freehand technique aided by lateral fluoroscopy: results of postoperative computed tomography in 114 patients. Spine J 2015;15:700–4.
crossref pmid
14. Gelalis ID, Paschos NK, Pakos EE, et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 2012;21:247–55.
crossref pmid pdf
15. Liljenqvist UR, Halm HF, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976) 1997;22:2239–45.
crossref pmid
16. Hicks JM, Singla A, Shen FH, Arlet V. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine (Phila Pa 1976) 2010;35:E465–70.
crossref pmid
17. Merloz P, Troccaz J, Vouaillat H, et al. Fluoroscopybased navigation system in spine surgery. Proc Inst Mech Eng H 2007;221:813–20.
crossref pmid
18. Kotani T, Akazawa T, Sakuma T, et al. Accuracy of pedicle screw placement in scoliosis surgery: a comparison between conventional computed tomography-based and O-arm-based navigation techniques. Asian Spine J 2014;8:331–8.
crossref pmid pmc
19. Macke JJ, Woo R, Varich L. Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population. J Robot Surg 2016;10:145–50.
crossref pmid pdf
20. Chaput CD, George K, Samdani AF, Williams JI, Gaughan J, Betz RR. Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion. Spine (Phila Pa 1976) 2012;37:E1305–9.
crossref pmid
21. Chen H, Guo K, Yang H, Wu D, Yuan F. Thoracic pedicle screw placement guide plate produced by three-dimensional (3-D) laser printing. Med Sci Monit 2016;22:1682–6.
crossref pmid pmc
22. Gadia A, Shah K, Nene A. Emergence of three-dimensional printing technology and its utility in spine surgery. Asian Spine J 2018;12:365–71.
crossref pmid pmc pdf
23. Kotani Y, Abumi K, Ito M, et al. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine (Phila Pa 1976) 2007;32:1543–50.
crossref pmid
24. Sakai Y, Matsuyama Y, Nakamura H, et al. Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery. J Spinal Disord Tech 2008;21:181–6.
crossref pmid
25. Pitteloud N, Gamulin A, Barea C, Damet J, Racloz G, Sans-Merce M. Radiation exposure using the O-arm(R) surgical imaging system. Eur Spine J 2017;26:651–7.
crossref pmid pdf
26. Barzilay Y, Liebergall M, Fridlander A, Knoller N. Miniature robotic guidance for spine surgery: introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres. Int J Med Robot 2006;2:146–53.
crossref pmid
27. Laudato PA, Pierzchala K, Schizas C. Pedicle screw insertion accuracy using O-arm, robotic guidance, or freehand technique: a comparative study. Spine (Phila Pa 1976) 2018;43:E373–8.
crossref pmid
28. D’Urso PS, Williamson OD, Thompson RG. Biomodeling as an aid to spinal instrumentation. Spine (Phila Pa 1976) 2005;30:2841–5.
crossref pmid
29. Guo F, Dai J, Zhang J, et al. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine. PLoS One 2017;12:e0171509.
crossref pmid pmc
30. Sugawara T, Higashiyama N, Kaneyama S, Sumi M. Accurate and simple screw insertion procedure with patient-specific screw guide templates for posterior C1-C2 fixation. Spine (Phila Pa 1976) 2017;42:E340–6.
crossref pmid
31. Takemoto M, Fujibayashi S, Ota E, et al. Additivemanufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J 2016;25:1698–705.
crossref pmid pdf
32. Liu K, Zhang Q, Li X, et al. Preliminary application of a multi-level 3D printing drill guide template for pedicle screw placement in severe and rigid scoliosis. Eur Spine J 2017;26:1684–9.
crossref pmid pdf
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 6 Web of Science
  • 7 Crossref
  • 6 Scopus
  • 5,472 View
  • 162 Download
Related articles in ASJ


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine
88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
Tel: +82-2-3010-3530    Fax: +82-2-3010-8555    E-mail: asianspinejournal@gmail.com                
Korean Society of Spine Surgery
27, Dongguk-ro, Ilsandong-gu, Goyang-si 10326, Korea
Tel: +82-31-966-3413    Fax: +82-2-831-3414    E-mail: office@spine.or.kr                

Copyright © 2024 by Korean Society of Spine Surgery.

Developed in M2PI

Close layer
prev next