Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model
Venkatesh Krishnan, Vicky Varghese, Gurunathan Saravana Kumar
Asian Spine J. 2016;10(3):414-421.   Published online 2016 Jun 16     DOI: https://doi.org/10.4184/asj.2016.10.3.414
Citations to this article as recorded by Crossref logo
The relationship of the posterior iliac interval and the S1 screw trajectory
Benjamin K.H. Ho, Lachlan Jackson, Ameen Farsakh, Jeremy Kam, Jonathon Ball
Journal of Clinical Neuroscience.2023; 111: 32.     CrossRef
Biomechanical evaluation of pedicle screw stability after 360-degree turnback from full insertion: effects of screw shape, pilot hole profile and bone density
Yun-Da Li, Ming-Kai Hsieh, Weng-Pin Chen, De-Mei Lee, Tsung-Ting Tsai, Po-Liang Lai, Ching-Lung Tai
Frontiers in Bioengineering and Biotechnology.2023;[Epub]     CrossRef
Screw Pullout Strength After Pedicle Screw Reposition: A Finite Element Analysis
Yu-Xing Ye, Da-Geng Huang, Ding-Jun Hao, Jia-Yuan Liu, Jia-Jia Ji, Jin-Niu Guo
Spine.2023; 48(22): E382.     CrossRef
The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines
Yuetian Wang, Lei Yang, Chunde Li, Haolin Sun
Global Spine Journal.2022; 12(2): 323.     CrossRef
Biomechanical comparison of pedicle screw fixation strength among three different screw trajectories using single vertebrae and one-level functional spinal unit
Ching-Lung Tai, Weng-Pin Chen, Mu-Yi Liu, Yun-Da Li, Tsung-Ting Tsai, Po-Liang Lai, Ming-Kai Hsieh
Frontiers in Bioengineering and Biotechnology.2022;[Epub]     CrossRef
Experimental investigation of pull-out performance of pedicle screws at different polyurethane (PU) foam densities
Ahmet Çetin, Durmuş Ali Bircan
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.2021; 235(6): 709.     CrossRef
Biomechanical design and analysis of auxetic pedicle screw to resist loosening
Yan Yao, Hao Yuan, Huiwen Huang, Jinglong Liu, Lizhen Wang, Yubo Fan
Computers in Biology and Medicine.2021; 133: 104386.     CrossRef
Stress distribution of different lumbar posterior pedicle screw insertion techniques: a combination study of finite element analysis and biomechanical test
Mingzhi Song, Kebin Sun, Zhonghai Li, Junwei Zong, Xiliang Tian, Kai Ma, Shouyu Wang
Scientific Reports.2021;[Epub]     CrossRef
Screw insertion torque as parameter to judge the fixation. Assessment of torque and pull-out strength in different bone densities and screw-pitches
Francesco Addevico, Massimo Morandi, Michelangelo Scaglione, Giovanni F. Solitro
Clinical Biomechanics.2020; 72: 130.     CrossRef
Comprehensive analysis on orthopedic drilling: A state-of-the-art review
Muhammad Jamil, Saima Rafique, Aqib Mashood Khan, Hussien Hegab, Mozammel Mia, Munish Kumar Gupta, Qinghua Song
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.2020; 234(6): 537.     CrossRef
Identification of Pedicle Screw Pullout Load Paths for Osteoporotic Vertebrae
Venkatesh Krishnan, Vicky Varghese, Gurunathan Saravana Kumar, Narayan Yoganandan
Asian Spine Journal.2020; 14(3): 273.     CrossRef
Pedicle Screw Designs in Spinal Surgery
Wei Ren Daniel Seng, Siaw Meng Chou, Shiblee S. Siddiqui, Jacob Y.L. Oh
Spine.2019; 44(3): E144.     CrossRef
Comparison of the Pullout Strength of Pedicle Screws According to the Thread Design for Various Degrees of Bone Quality
Shen, Kim, Kang, Yeom
Applied Sciences.2019; 9(8): 1525.     CrossRef
Comparison of pullout strength of pedicle screws following revision using larger diameter screws
Vicky Varghese, Venkatesh Krishnan, Gurunathan Saravana Kumar
Medical Engineering & Physics.2019; 74: 180.     CrossRef
Pullout Strength Predictor: A Machine Learning Approach
Ravi Khatri, Vicky Varghese, Sunil Sharma, Gurunathan Saravana Kumar, Harvinder Singh Chhabra
Asian Spine Journal.2019; 13(5): 842.     CrossRef
In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application
Christian Liebsch, Julia Zimmermann, Nicolas Graf, Christoph Schilling, Hans-Joachim Wilke, Annette Kienle
Journal of the Mechanical Behavior of Biomedical Materials.2018; 77: 578.     CrossRef
Testing Pullout Strength of Pedicle Screw Using Synthetic Bone Models: Is a Bilayer Foam Model a Better Representation of Vertebra?
Vicky Varghese, Venkatesh Krishnan, Gurunathan Saravana Kumar
Asian Spine Journal.2018; 12(3): 398.     CrossRef
Evaluating Pedicle-Screw Instrumentation Using Decision-Tree Analysis Based on Pullout Strength
Vicky Varghese, Venkatesh Krishnan, Gurunathan Saravana Kumar
Asian Spine Journal.2018; 12(4): 611.     CrossRef
The Effects of Geometrical Parameters of the Pedicle Screw on Its Pullout Strength: In-Vitro Animal Tests
Sheida Vafadar, Gholamreza Rouhi
Journal of Orthopedic and Spine Trauma.2017;[Epub]     CrossRef
Effect of zoledronic acid on lumbar spinal fusion in osteoporotic patients
Qirui Ding, Jian Chen, Jin Fan, Qingqing Li, Guoyong Yin, Lipeng Yu
European Spine Journal.2017; 26(11): 2969.     CrossRef