Asian Spine J Search

CLOSE


Asian Spine J > Volume 13(1); 2019 > Article
Srivastava, Nanda, Mahajan, Nanda, Batra, Mishra, Pandita, and Chhabra: Feasibility of Sub-Axial Cervical Laminar Screws, Including C7, in the Indian Population: A Study on 50 Patients Using Computed Tomography-Based Morphometry Measurements

Abstract

Study Design

Observational study of computed tomography (CT) data.

Purpose

We performed a CT-based radiographic analysis of sub-axial cervical lamina in the Indian population to assess the feasibility of laminar screws.

Overview of Literature

Morphometric studies have been performed for populations of various ethnic groups, but none exist for Indian populations.

Methods

Cervical spine CT scans of 50 adults with a minimum slice thickness of <2 mm (0.5–2 mm) were obtained from the database of a single center in northern India. Measurements (e.g., length, thickness, and height) were taken in millimeters along the axial, coronal, and sagittal planes. Three measurements were made to assess laminar anatomy, namely, the translaminar/screw length, laminar thickness, and sagittal laminar height.

Results

The final sample comprised 500 laminae in 50 patients, resulting in 1,500 measurements. The mean translaminar lengths of the C3, C4, C5, C6, and C7 laminae were 19.48 mm, 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.60 , 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.61 , 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 20.49 , 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, and 22.85 mm, respectively. The mean thick- , and 22.85 mm, respectively. The mean thick , and 22.85 mm, respectively. The mean thicknesses of these cervical laminae were 3.12 mm, 2.62 mm, 2.56 mm, 3.47 mm, and 5.20 mm, respectively. The mean sagittal heights of these laminae were 9.38 mm, 9.80 mm, 10.12 mm, 11.31 mm, and 13.84 mm, respectively. Except for the C7 vertebrae, all other levels had a success rate of <10% in the Indian population using the criteria of a laminar height of at least 9 mm and thickness of 4.5 mm. Limited success was achieved at the C5, C6, and C3 levels.

Conclusions

To the best of our knowledge, the present study is the only series on the feasibility of laminar screws in the sub-axial cervical spine in the Indian population. We found that Indian patients have smaller anatomical dimensions and thus, are not suitable for laminar screws in the sub-axial cervical spine, barring C7, which is contrary to findings for populations in western and south Asian countries.

Introduction

Posterior instrumentation of the cervical spine and fusion with or without decompression is extensively used for the treatment of several cervical spine pathologies [1]. It may be used alone or in combination with the standard anterior cervical approach to provide immediate stabilization along with adequate decompression, allowing for early mobility [2]. The workhorse of posterior cervical instrumentation is lateral mass screw fixation, which is technically easy to place. However, due to anatomical variations, it may not be the ideal choice in several conditions, particularly at lower levels where because of size and anatomical considerations, the placement becomes technically difficult. In such cases, there is a higher pullout rate along with lower pullout strength into the bone [3,4], with a slight possibility of injury to the vertebral artery in foramen transversarium. To address these issues, cervical pedicle screws were popularized by Abumi et al. [5-7]. Unfortunately, placing a cervical pedicle screw in the sub-axial spine is a much more technically demanding procedure than lateral mass fixation, and it may place both the vertebral artery and spinal cord at risk because of their close proximity to the screw. The rate of radiological malposition is also reported to be higher [8,9].
In view of the above limitations, recent reports on cervical laminar screws have highlighted their simplicity and safety relative to pedicle screws [10-12]. Sub-axial cervical spine morphometry reports have noted wide anatomical variability in the dimensions of the sub-axial lamina, both in pediatric and adult populations [13-15]. Biomechanically, it is better than the lateral mass as the stress around the pedicle body complex and range of movement anticipated for the construct are smaller [16]. To date, there have been only few computed tomography (CT)-based analyses of the morphometry and feasibility of sub-axial cervical spine laminar screws [14,17,18]. However, to the best of our knowledge, none of these analyses were conducted in an Indian population.
The primary aim of this study was to conduct a CT-based radiographic analysis of the sub-axial cervical lamina in an Indian population to assess the feasibility of laminar screws and to identify ethnic differences in morphometry because knowledge on ethnic variations may allow limited use of this technique in this population.

Materials and Methods

After obtaining the appropriate ethical approval, 50 adult cervical spine CT scans with minimum slice thickness of <2 mm (0.5–2 mm) were obtained from the database of a single center in New Delhi, northern India. The raw volumetric axial images were taken, and CT reconstruction in the sagittal and coronal planes was performed using software (Radiant version 3.2.2; http://www.radiantcms.org/). Patients with incomplete cervical region scans were excluded. Cases with a demonstrable lesion in the sub-axial cervical spine in the form of a fracture, tumor, infection, inflammatory disease, or congenital malformation were also excluded.
Measurements (e.g., length, thickness, and height) were taken in millimeters along the axial, coronal, and sagittal planes. Three measurements were made to assess laminar anatomy, namely, the translaminar/screw length, laminar thickness, and sagittal laminar height.
The translaminar/screw length was measured using a technique that involves measurements of the axial plane from the junction of the lateral mass and lamina to the contralateral outer cortex of the spinous process (Fig. 1A). The next measurement was the thickness of the lamina taken at the isthmus or narrowest part of the lamina, spanning from the ventromedial to the dorsolateral sides of the central portion bilaterally from C3 to C7 (Fig. 1B). Lastly, the sagittal measurement or laminar height was measured bilaterally along the parasagittal plane from C3 through C7, which was defined as the most rostral point of the lamina, terminating at the most caudal portion of the lamina of the same vertebrae on the sagittal plane (Fig. 1C). The three measurements were performed after the two authors agreed on the image based on the above criteria using PACS software (Radiant) to achieve consistent observations.
Descriptive statistics, including the mean, standard deviation, and range, were calculated. Differences in measurements of the right and left laminar dimensions, along with sex variation, were assessed using Student t-tests. The literature was then reviewed along with the resulting data to identify variations and their amenability to instrumentation.

Results

1. Patient demographic data

Fifty (25 males, 25 females) cervical spine CT scans were evaluated in this study. The mean age of male patients was 54±12.1 years (range, 31–75 years) and the mean age of female patients was 49.2±15.2 years (range, 22–80 years). Age did not significantly differ between sexes (p=0.45).

2. Morphometric analysis

The final study sample comprised 500 laminae in 50 patients, giving 1,500 measurements. The mean translaminar lengths of the C3, C4, C5, C6, and C7 laminae were 19.48 mm, 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thicknesses of these cervical laminae were 3.12 mm, 2.62 mm, 2.56 mm, 3.47 mm, and 5.20 mm, respectively. The mean sagittal heights of these laminae were 9.38 mm, 9.80 mm, 10.12 mm, 11.31 mm, and 13.84 mm, respectively (Table 1).
Measurements for individual levels for both sexes were done as depicted in Table 2. There were statistically significant differences in laminar thickness for males and females, particularly at C7 (p=0.0017). In the morphometric values, no statistically significant differences were noted between the right and left sides at all levels.

3. Success rate of screw placement

As depicted in Table 3, the success rate of screw insertion was calculated using the criteria of Chern et al. [13], Shin et al. [17], and Alvin et al. [18]. Besides the C7 vertebrae, all other levels had success rates of <10% in the Indian population using the criteria of a laminar height of at least 9 mm and thickness of 4.5 mm. The C4 did not allow placement of laminar screws by the criteria, whereas limited success was noted at the C5, C6, and C3 levels.

Discussion

Laminar screws were popularized by Wright [19] for C2 as a safer alternative to pedicle screws in the C1–C2 constructs. This technique allows direct insertion under regular vision, eliminating the need for navigation or fluoroscopy, and is not limited by the positioning of vascular structures with good biomechanical stability. Encouraged by the use of C2 laminar screws, Hong et al. [14] extended their use in the sub-axial spine. Subsequently, many authors have reported the feasibility and use of this technique in a limited way, but none have done so in the context of Indian patients. Because ethnic variation has been reported for anatomical structures, such as pedicles and condyles [20-22], this study focused on the ability to apply this technique to Indian populations.

1. Morphometric Measurements

Laminar thickness, which is the most critical dimension for placing laminar screws, was at its maximum at C7 (>5 mm) and <3 mm at all other levels, barring C3 where the mean was 3.12 mm. This is mostly in line with reports by Xu et al. [23] and Chern et al. [13] of pediatric patients, but lower than the values reported by Alvin et al. [1 8] where the average thickness was >4 mm at all sub-axial cervical levels. This finding underscores the wide varia - tion in anatomy. Males were significantly more likely than females to have a laminar thickness that allows safe place - ment of laminar screws at C7.
The laminar length, which determined the length of laminar screw, was smaller than previously reported values. The mean was consistently <24 mm at all levels, including C7. This is important as a 24-mm screw length was used in biomechanical and anatomical studies on laminar screws [14,24], and these may thus, not be suit- [14,24], and these may thus, not be suit [14,24], and these may thus, not be suitable for Indian patients as none would qualify for this technique. This finding warrants further biomechanical research focused on the effect of screw length and pullout strength/biomechanical stability in the above technique.
The laminar height was >9 mm at all levels in the subaxial spine, which should allow bilateral placement of adequately sized screws, assuming the commonly used screw dimensions of 3.5 mm. The maximum sagittal height was noted at C7, and the mean values decreased moving from the caudal to cephalad level. Our findings were similar to those by Alvin et al. [18] for mean sagittal diagonal mea - surements, but with consistent measurements of >10 mm at all levels.

2. Anatomical feasibility of screw placement

The reported feasibility of placing 3.5 mm laminar screws, based on anatomical measurements, varies across studies. In this study, we applied the criteria used by Chern et al. [13], Shin et al. [17], Alvin et al. [18] as outlined in Table 3. Based on these criteria, laminar screws are not feasible at C3, C4, C5, and C6; C7 was the only level where the acceptability was >80% for at least two criteria. This reso - nates with work by Cardoso et al. [24] that reported 100% feasibility in C7 lamina in nine patients in a series for 3.5-mm screws. The study by Shin et al. [17] reported higher feasibility of C7 laminar screws and screws at other levels compared to our study. However, they did not recom - mend placing laminar screws at C4 or C5, and recom - mended extreme caution at C3 and C6 (approximately 30%). This emphasizes the anatomical limitations of laminae in Indian patients and possible ethnic differences.

3. Limitations

The study investigated a limited number of patients and their CT scans to assess the morphometry of the laminae of the sub-axial cervical spine in Indian patients. The dataset mainly comprised patients from northern India and may thus, not represent the full spectrum of India’s ethnic diversity. Moreover, we did not perform a computer simulation and relied on criteria published by other authors to assess the feasibility of the screws. Finally, height, weight, and body mass index were not considered in this study. Despite these shortcomings, this is the first study to assess this novel technique in an Indian population.

Conclusions

To the best of our knowledge, the present study is the only series that assessed the feasibility of laminar screws in the subaxial cervical spine in an Indian population. We found that Indian patients, by virtue of genetic and ethnic variations, have smaller anatomical dimensions that make them unsuitable for laminar screws in the subaxial cervical spine, barring C7, contrary to reports from western and south Asian countries. These findings suggest that standard implant dimensions need to be altered and supplemented by biomechanical studies for this technique to be successful in Indian populations, and such alterations may include a smaller diameter and length screws that are custom built for use in this technique.

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Acknowledgments

This study was supported by Research grant from AO Spine India.

Fig. 1.
Computed tomography images with representative measurement of translaminar length (A), translaminar thickness (B), and sagittal height (C).
asj-2018-0110f1.jpg
Table 1.
Mean morphometric (i.e., translaminar length, thickness, height, and sagittal-diagonal) measurements at each vertebral level
Level Lamina length Laminar thickness Laminar sagittal height
C3 19.48±2.03 3.12±0.77 9.38±1.59
C4 19.60±2.08 2.62±0.65 9.80±1.44
C5 19.61±2.13 2.56±0.66 10.12±1.54
C6 20.49±2.41 3.47±0.88 11.31±1.82
C7 22.85±2.38 5.20±0.79 13.84±1.37

Values are presented as mean±standard deviation.

Table 2.
The mean morphometric (i.e., translaminar length, thickness, and sagittal-height) measurements at each vertebral level for men and women
Vertebrae Length
Thickness
Sagittal height
M F M F M F
C3 19.8±1.7 (16.5–28.3) 19.1±2.20 (13.7–24.5) 3.22±0.77 (1.3–5.2) 3.02±0.75 (1.80–5.40) 9.89±1.59 (6.90–13.4) 8.8±1.42 (5.10–12.6)
C4 19.51±2.22 (9.4–23.7) 19.48±2.41 (14.8–24.9) 2.70±0.65 (1.60–4.20) 2.53±0.64 (1.30–4.40) 9.29±1.36 (7.00–12.4) 10.30±1.31 (7.2–12.9)
C5 20.23±2.19 (16.3–23.4) 18.99±1.89 (18.4–24) 2.64±0.65 (1.20–3.90) 2.46±0.66 (1.40–4.60) 10.69±1.32 (7.40–12.8) 9.63±1.57 (4.80–12.5)
C6 21.7±1.85 (17.4–25.9) 19.31±2.34 (13.6–23.6) 3.66±0.90 (1.50–5.90) 3.29±0.82 (1.90–5.40) 11.75±1.55 (7.1–14.6) 10.87±1.97 (5.50–14.5)
C7 23.59±2.53 (17.5–30.1) 22.11±1.97 (17.9–27.2) 5.43±0.70 (3.7–6.9) 4.97±0.80 (3.3–6.8) 14.10±1.20 (11.0–16.9) 13.58±1.40 (11.1–17.8)

Values are presented as mean±standard deviation (range).

M, male; F, female.

Table 3.
Feasibility of laminar screw using various published criteria
Variable Feasibility using criteria of Chern et al. [13] Feasibility using modified criteria of Shin et al. [17] Feasibility using criteria of Alvin et al. [13]
Criteria
 Laminar height (mm) ≥9 - ≥7
 Laminar thickness (mm) ≥4.5 ≥4.0 ≥4.5
 Screw length (mm) - 25 ≥7
Vertebral level (%)
 C3 6 0 7
 C4 0 0 0
 C5 1 0 1
 C6 8 1 13
 C7 83 12 83

Values are presented as mean±standard deviation (range).

M, male; F, female.

References

1. Hedequist DJ, Emans JB. Cervical spine instrumentation in children. J Am Acad Orthop Surg 2016 24:370–8.
crossref pmid
2. Cheung KM, Mak KC, Luk KD. Anterior approach to cervical spine. Spine (Phila Pa 1976) 2012 37:E297–302.
crossref pmid
3. Heller JG, Silcox DH 3rd, Sutterlin CE 3rd. Complications of posterior cervical plating. Spine (Phila Pa 1976) 1995 20:2442–8.
crossref pmid
4. Fehlings MG, Cooper PR, Errico TJ. Posterior plates in the management of cervical instability: long-term results in 44 patients. J Neurosurg 1994 81:341–9.
crossref pmid
5. Abumi K, Itoh H, Taneichi H, Kaneda K. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 1994 7:19–28.
crossref pmid
6. Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine (Phila Pa 1976) 1997 22:1853–63.
crossref pmid
7. Abumi K, Shono Y, Taneichi H, Ito M, Kaneda K. Correction of cervical kyphosis using pedicle screw fixation systems. Spine (Phila Pa 1976) 1999 24:2389–96.
crossref pmid
8. Nakashima H, Yukawa Y, Imagama S, et al. Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 2012 16:238–47.
crossref pmid
9. Kast E, Mohr K, Richter HP, Borm W. Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 2006 15:327–34.
crossref pmid
10. Kretzer RM, Hu N, Kikkawa J, et al. Surgical management of two- versus three-column injuries of the cervicothoracic junction: biomechanical comparison of translaminar screw and pedicle screw fixation using a cadaveric model. Spine (Phila Pa 1976) 2010 35:E948–54.
crossref pmid
11. Kretzer RM, Chaput C, Sciubba DM, et al. A computed tomography-based feasibility study of translaminar screw fixation in the upper thoracic spine. J Neurosurg Spine 2010 12:286–92.
crossref pmid
12. Wang MY. Cervical crossing laminar screws: early clinical results and complications. Neurosurgery 2007 61(5 Suppl 2): 311–5.
crossref pmid pdf
13. Chern JJ, Chamoun RB, Whitehead WE, Curry DJ, Luerssen TG, Jea A. Computed tomography morphometric analysis for axial and subaxial translaminar screw placement in the pediatric cervical spine. J Neurosurg Pediatr 2009 3:121–8.
crossref pmid
14. Hong JT, Sung JH, Son BC, Lee SW, Park CK. Significance of laminar screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 2008 33:1739–43.
crossref pmid
15. Jea A, Johnson KK, Whitehead WE, Luerssen TG. Translaminar screw fixation in the subaxial pediatric cervical spine. J Neurosurg Pediatr 2008 2:386–90.
crossref pmid
16. Benke MT, O’Brien JR, Turner AW, Yu WD. Biomechanical comparison of transpedicular versus intralaminar C2 fixation in C2-C6 subaxial constructs. Spine (Phila Pa 1976) 2011 36:E33–7.
crossref pmid
17. Shin SI, Yeom JS, Kim HJ, Chang BS, Lee CK, Riew KD. The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software. Spine J 2012 12:577–84.
crossref pmid
18. Alvin MD, Abdullah KG, Steinmetz MP, et al. Translaminar screw fixation in the subaxial cervical spine: quantitative laminar analysis and feasibility of unilateral and bilateral translaminar virtual screw placement. Spine (Phila Pa 1976) 2012 37:E745–51.
crossref pmid
19. Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004 17:158–62.
crossref pmid
20. Srivastava A, Nanda G, Mahajan R, et al. Computed tomography-based occipital condyle morphometry in an Indian population to assess the feasibility of condylar screws for occipitocervical fusion. Asian Spine J 2017 11:847–53.
crossref pmid pmc
21. Srivastava A, Mahajan R, Nanda A, et al. Morphometric study of C1 pedicle and feasibility evaluation of C1 pedicle screw placement with a novel clinically relevant radiological classification in an Indian population. Asian Spine J 2017 11:679–85.
crossref pmid pmc
22. Acharya S, Dorje T, Srivastava A. Lower dorsal and lumbar pedicle morphometry in Indian population: a study of four hundred fifty vertebrae. Spine (Phila Pa 1976) 2010 35:E378–84.
crossref pmid
23. Xu R, Burgar A, Ebraheim NA, Yeasting RA. The quantitative anatomy of the laminas of the spine. Spine (Phila Pa 1976) 1999 24:107–13.
crossref pmid
24. Cardoso MJ, Dmitriev AE, Helgeson MD, et al. Using lamina screws as a salvage technique at C-7: computed tomography and biomechanical analysis using cadaveric vertebrae: laboratory investigation. J Neurosurg Spine 2009 11:28–33.
crossref pmid
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 5 Web of Science
  • 5 Crossref
  • 5 Scopus
  • 3,491 View
  • 131 Download
Related articles in ASJ


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine
88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
Tel: +82-2-3010-3530    Fax: +82-2-3010-8555    E-mail: asianspinejournal@gmail.com                
Korean Society of Spine Surgery
27, Dongguk-ro, Ilsandong-gu, Goyang-si 10326, Korea
Tel: +82-31-966-3413    Fax: +82-2-831-3414    E-mail: office@spine.or.kr                

Copyright © 2024 by Korean Society of Spine Surgery.

Developed in M2PI

Close layer
prev next